Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.

Wenhui Zhu, Mingming Chen, Yixuan Guo, Bin Zhang, Chunliu Luo

Journal of medical Internet research · 2026

Abstract originale

BACKGROUND: Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear. OBJECTIVE: This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta‑Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta‑Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I² statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. RESULTS: Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] -4.52, 95% CI -8.38 to -0.67, PI -9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%-2.11%, PI 1.85%-2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98-35.24, PI -16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R²=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high. CONCLUSIONS: Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Parole chiave

HumansSleep Initiation and Maintenance DisordersWearable Electronic DevicesRandomized Controlled Trials as TopicSleepDigital HealthAdultDigital MediaTreatment Outcomedigital healthinsomnia symptomsmeta-analysissleep problemswearable electronic devices
Leggi il testo integrale originale

Testo estratto dalla pubblicazione: sono esclusi immagini, media, supplementi e parti soggette a diritti distinti.

Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials

Abstract

Background

Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear.

Objective

This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression.

Methods

This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta‑Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta‑Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I² statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach.

Results

Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] −4.52, 95% CI −8.38 to −0.67, PI −9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%‐2.11%, PI 1.85%‐2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98‐35.24, PI −16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R²=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high.

Conclusions

Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Introduction

Insomnia, defined as persistent difficulty in initiating or maintaining sleep accompanied by clinically significant daytime impairment [1,2], remains one of the most prevalent sleep disorders worldwide. Epidemiological estimates indicate that approximately 10% to 20% of the general adult population meet diagnostic criteria for insomnia disorder [1,3], with prevalence rising markedly with age, and women being 1.3 to 1.7 times more likely to be affected than men across all age groups [4,5]. Beyond its immediate impact on sleep quality, insomnia constitutes a major risk factor for various mental disorders, such as depression, anxiety, and alcohol dependence, and is additionally associated with diminished quality of life and increased all-cause mortality [4,6-9], thereby imposing a substantial economic and health care burden on society [10]. In the United States alone, the direct costs of insomnia-related medical care, combined with indirect costs from workplace productivity loss, absenteeism, and accidents, have been estimated to exceed US $100 billion annually [11,12]. In aging societies across East Asia and Europe, this burden is further exacerbated by the disproportionately high prevalence of insomnia among older adults [13,14] and the corresponding rise in demand for chronic disease management [15]. Given this profound public health impact, identifying safe, effective, and scalable interventions for insomnia remains a critical priority for health care systems globally.

The management of insomnia encompasses psychological, behavioral, pharmacological, and complementary approaches [3,9]. Among these, cognitive behavioral therapy for insomnia (CBT-I) is recommended as first-line treatment on the basis of robust empirical evidence [2,5]. However, its widespread implementation is severely constrained. The global shortage of trained CBT-I therapists [16], together with high per-session costs (which average US $260 in the United States [17]) and marked geographic disparities in service availability [17], means that the vast majority of patients with insomnia rarely receive guideline-recommended behavioral treatment [2,3,5]. Pharmacological treatments, including benzodiazepine receptor agonists and Z-drugs, provide short-term symptomatic relief but entail substantial risks with long-term use [18], including physical dependence, tolerance, rebound insomnia on discontinuation, cognitive impairment, next-day sedation, and increased fall risk, especially in older adults [19]. Consequently, clinical guidelines universally recommend limiting hypnotic use to the lowest effective dose and the shortest necessary duration, with pharmacotherapy generally restricted to short‑term use of no more than 4 to 5 weeks [20]. The persistent gap between high treatment demand and limited access to evidence-based nonpharmacological therapies highlights the need for scalable alternatives that do not require the infrastructure and workforce associated with traditional CBT-I.

In recent years, digital therapeutics, particularly wearable devices, have emerged as a rapidly advancing frontier in sleep medicine [21-23]. Adoption of wearable sleep technology, including smartwatches, wristbands, head-mounted electroencephalography (EEG) systems, and therapeutic filtered-light glasses, has grown substantially, driven by increasing public awareness of sleep health and advances in miniaturized sensing technology [24,25]. These devices enable continuous, real-time physiological monitoring (eg, heart rate variability, actigraphy [26]) and can provide active therapeutic functions such as acoustic stimulation, transcranial electrical stimulation, and biofeedback-based sleep retraining [2,26-28]. Nevertheless, the available synthesized evidence on the efficacy of stand-alone wearable devices for insomnia remains limited.

Several earlier systematic reviews have sought to synthesize evidence in this field. For instance, Jung et al [8] examined mobile apps for insomnia but did not specifically focus on wearable devices used as stand-alone interventions. Bai et al [29] and Hwang et al [30] assessed digital CBT-I programs rather than the wearable hardware itself. Baron et al [31] and Glazer Baron et al [32] centered their reviews on measurement rather than on therapeutic efficacy. Lai et al [33] reviewed wearable-delivered interventions but pooled heterogeneous populations and did not include any studies published after December 2021. Critically, however, few prior reviews have systematically distinguished between objectively measured sleep parameters and patient-reported subjective sleep outcomes.

Critically, this review was designed to address several knowledge gaps that were not fully addressed in previous meta-analyses. First, rather than aggregating composite digital therapies (eg, wearables combined with app-guided psychotherapy), we focused exclusively on stand-alone wearable interventions to isolate their pure therapeutic effect. Second, we explicitly stratified outcomes into objective sleep parameters (measured by actigraphy or polysomnography) and subjective patient-reported outcomes, given that these 2 domains frequently yield discrepant findings in insomnia research and carry distinct clinical implications. Third, we performed targeted meta-regression to quantitatively investigate sources of heterogeneity in insomnia severity scores, an approach not systematically applied in prior reviews. Fourth, we used the confidence distribution approach proposed by Nagashima et al [34] to compute prediction intervals (PIs), thereby going beyond average pooled estimates to provide a more reliable estimate of the true effect distribution across different clinical settings and populations.

Taken together, the existing literature remains inadequate, owing to fragmentation across technologies, heterogeneity in the conceptualization and measurement of sleep outcomes, and a scarcity of evaluations that isolate the stand-alone effect of wearable hardware while simultaneously distinguishing objective end points from subjective ones and exploring sources of heterogeneity. This review addresses these limitations by concentrating exclusively on stand-alone wearable devices, categorizing outcomes according to objective and subjective measures, and using more conservative statistical methods, including the Hartung-Knapp-Sidik-Jonkman (HKSJ) approach [35] and Nagashima-corrected PIs [34]. Accordingly, the aim of this systematic review and meta-analysis was to evaluate the therapeutic efficacy of stand-alone wearable digital interventions on objective and subjective sleep outcomes relative to various control conditions in adults with insomnia.

Methods

Protocol and Guidance

This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 statement [36] and was registered prospectively with PROSPERO (International Prospective Register of Systematic Reviews). The PRISMA 2020 expanded checklist is provided in Checklist 1. No deviations from the registered protocol occurred during the study.

Eligibility Criteria

We included randomized controlled trials (RCTs) [37] that used wearable-delivered interventions for adults with insomnia. Eligible participants were adults with an insomnia severity index (ISI) score >7 or those meeting the diagnostic criteria for insomnia disorder as defined by established international classification systems (eg, the Diagnostic and Statistical Manual of Mental Disorders or the International Classification of Sleep Disorders). Wearable digital devices (eg, smartwatches, wristbands, and rings) were defined as devices equipped with sleep monitoring as well as active therapeutic functions (eg, acoustic stimulation, filtered light glasses). The intervention was required to be compared against a control condition such as usual care, a sham device, or a waitlist control.

Exclusion criteria were as follows: (1) acute or critical illnesses in participants, (2) intervention duration of less than 1 week, (3) unavailability of full text of the article, and (4) duplicate publications or studies with overlapping data.

Information Sources

We searched the following electronic databases from inception to April 30, 2025, without language restrictions: PubMed, Embase, Web of Science, PsycINFO, and the Cochrane Central Register of Controlled Trials. The search was updated on May 18, 2026, to capture newly published studies. The full search strategies for each database are provided in Multimedia Appendix 1.

Search Strategy

The search was reported according to the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta-Analyses literature search extension) guideline [38]. We searched PubMed, Embase, Web of Science, PsycINFO, and the Cochrane Library from inception to April 30, 2025 (updated May 18, 2026). The search combined controlled vocabulary (MeSH in PubMed/Cochrane, Emtree in Embase) and free-text terms for 3 domains: wearable devices (eg, “wearable electronic devices,” “actigraphy,” “smartwatch”), insomnia (eg, “insomnia,” “sleep initiation and maintenance disorders”), and RCTs (eg, “randomized controlled trial,” “RCT”). No language or date restrictions were applied. The detailed search strategies for each database are provided in Multimedia Appendix 1. The PRISMA-S checklist is provided in Checklist 2. Backward and forward citation searches of included studies were also performed.

No multidatabase searching, independent registry searches, online browsing, contacting authors, use of published search filters, adaptations from prior reviews, or formal peer review were performed. Each database was searched separately.

Selection Process

Two independent reviewers (WZ and MC) screened the titles, abstracts, and full texts of all retrieved articles. Studies assessed as potentially relevant or unclear at the title and abstract stage were obtained in full text and reevaluated. Any disagreements between the reviewers were resolved through discussion or by consultation with a third investigator (YG).

Data Collection Process

Data were extracted independently by 2 reviewers (WZ and MC) using a standardized data extraction form. Any disagreements were resolved through discussion or consultation with a third reviewer (YG). When data were missing or unclear, we contacted the corresponding authors of the original studies via email. No automation tools were used in the data collection process.

Data Items

For each included study, we extracted the primary outcome (ISI), secondary outcomes (objective sleep parameters: total sleep time [TST], sleep-onset latency [SOL], wake after sleep onset [WASO], sleep efficiency [SE]; and subjective sleep parameters: Pittsburgh Sleep Quality Index [PSQI], subjective TST, SOL, WASO, SE, Epworth Sleepiness Scale [ESS], and single-item sleep quality), and other variables (first author, year, country, design, participant characteristics, intervention details, comparator, attrition, intention-to-treat or missing data methods, trial registration, and funding).

Study Risk-of-Bias Assessment

The Cochrane Risk-of-Bias 2.0 (RoB 2.0) tool for randomized trials was used to evaluate the methodological quality of the included studies across 5 bias domains. Assessments were carried out independently by 2 reviewers (WZ and MC).

Effect Measures

For continuous outcomes (ISI, TST, SOL, WASO, SE, ESS, PSQI, and sleep quality), the effect measure was the mean difference (MD) with a 95% CI. When different scales were used for the same construct (eg, different sleep quality measures), we planned to use the standardized mean difference (SMD; Hedges g). However, all included studies reported outcomes on the same or directly convertible metrics, so MD was used throughout. All included trials used identical measurement units for each sleep parameter (eg, minutes for SOL, TST, and WASO and percentages for SE), enabling direct pooling with MD rather than SMD. Between-study differences in absolute values reflect clinical and demographic heterogeneity in study populations rather than any inconsistency in outcome scaling.

Synthesis Methods

Studies were grouped by outcome domain (ISI, objective sleep parameters, and subjective sleep parameters). Postintervention means and SDs were extracted; when only change scores were reported, the postintervention SD was calculated using a correlation coefficient of 0.5 [39]. Meta-analyses were performed using a random-effects model with the HKSJ correction (metafor package in R [R Foundation for Statistical Computing]) to reduce the risk of inflated type I errors [36,40], with heterogeneity assessed using I² statistics and Q tests. Nagashima-corrected 95% PIs [34] were calculated for all pooled outcomes and displayed in forest plots. To explore heterogeneity, meta-regression was conducted only for ISI with 3 prespecified moderators (control type, intervention duration, and device-wearing position). Sensitivity analyses included leave-one-out analysis for ISI and rerunning all meta-analyses after the updated literature search.

Reporting Bias Assessment

Funnel plots and Egger regression test were used to examine small-study effects (not publication bias directly). For outcomes with fewer than 10 studies, these tests were not performed due to limited statistical power. No trim-and-fill or other adjustment methods were applied. No other reporting bias assessments were conducted.

Certainty Assessment

The certainty of evidence for each outcome was evaluated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. Two reviewers (WZ and MC) independently rated the evidence across 5 domains: risk of bias, inconsistency, indirectness, imprecision, and publication bias. Disagreements were resolved by consensus. The overall certainty was graded as high, moderate, low, or very low. Outcomes with fewer than 3 studies were not graded.

Results

Study Selection

Of the 3815 records identified through database searching, 3799 were excluded after the removal of duplicates and the exclusion of irrelevant studies. All studies included independent participants, and no double-counting occurred. We updated the literature search on May 18, 2026, adding 2 new RCTs, and conducted a reanalysis of the statistics. The remaining 16 RCTs [41-56] met the eligibility criteria and were included in the final analysis. The study selection process is summarized in the PRISMA flow diagram (Figure 1).

Study Characteristics

Most studies reported low-to-moderate attrition rates. However, Aji et al [42] reported a high dropout rate (40/91, 44.0% among app initiators), with significantly more dropouts in the control group than in the intervention group, which the authors attributed to the fully digital, unsupervised design, and lack of face-to-face contact. Zabrecky et al [56] reported a dropout rate of 23.1% (9/39), mainly due to scheduling conflicts (n=4), inability to tolerate MRI scanning (n=2), and unspecified reasons (n=3), with no separate reporting by randomization group. For the remaining 8 studies, attrition rates ranged from 0% to 16%, and reasons for dropout were mostly unrelated to the intervention.

Among the 16 included RCTs, a total of 910 participants were enrolled across all studies, with sample sizes ranging from 14 to 152 per trial. A summary of the characteristics of the included studies is presented in Table 1. The publication years of the included studies spanned from 2017 to 2026; 11 [41-43,47-52,54,56] reported the ISI, 9 [45,47-52,54-56] reported TST, and 12 [41,43,45-52,54,55] contained objective sleep data, while 10 [41-43,46-49,51,52,55] included subjective sleep outcomes. The comparators consisted of sham interventions [41,43-49,52,53,55], waitlist [50,56], usual care [42,51], and active control [54]. Interventions were delivered via wearable devices: head-mounted devices [41,44-46,48,50,52,54], therapeutic filtered light glasses [47,49], neck-worn devices [43,53], ear-worn devices [55], and wristbands [42,51,56]. The intervention duration ranged from 2 weeks to 3 months. For all outcomes, posttreatment values were extracted to calculate effect sizes, as detailed in the “Methods” section.

Table 1. Characteristics of the included studies.

Author,year, country Design Population Samplesize Intervention Control Outcomes measures Attrition (%) ITTa/MDMb Protocol/registration Grant

Aji et al [42], 2022, Australia 2-arm RCTc ISId≥15 and PSQIe global>5 (42.6±10.7) Tf: 128Ig: 62Ch: 66 Wearable technology (Fitbit Charge 2) dBTii only ISI, daytime sleepiness (ESSj) 44 No/No No/Yes Yes

Anderson et al [43], 2025, United States 2-arm RCT ISI≥15 (40.4±12.1) T: 58I: 27C: 31 Evolv28 (wearable neckband device) Sham device Primary: ISISecondary: sleep duration, WASOk (min), SEl (%)Objective: (actigraphy) TSTm (min), SE (%), WASO (min) 8.47 Yes/Yes Yes/Yes Yes

Bressler et al [44], 2023, United States RCT ISI≥21 and PSQI global>5 (33.0±6.6) T: 48I: 24C: 24 Elemind Neuromodulation Device(a wearable EEGn) Sham device Sleep physiology metrics: sleep stage scoring, SOLo, phase tracking accuracy of alpha oscillations (8‐12 Hz)Subjective: (sleep diary) bedtime, wake time, sleep quality 0 No/No No/No Yes

Chen et al [45], 2026, China 2-arm RCT PSQI>7 (I: 20.85±2.2; C: 20.44±1.7) T: 20I: 10C: 10 cTBSp Sham device Objective (actigraphy): SOL, TST, TAq, SFIr 0 Yes/No No/No Yes

Curry et al [46], 2024, United Kingdom 2-arm RCT ISI≥15 (40.8±13.5) T: 126I: 61C: 65 Modius Sleep device Sham device Primary: change in ISI scoreSecondary: PSQI, RAND 36-Item Short Form Survey, caffeine diaries 15.65 Yes/Yes Yes/Yes Yes

Esaki et al [47], 2020, Japan 2-arm RCT Bipolar disorder ISI≥8 (I: 44.1±11.8; C: 41.1±10.4) T: 43I: 21C: 22 Blue-blocking orange glasses Clear placebo glasses Objective (actigraphy): SE, SOL, WASO, TSTSubjective: VASs, ISI, MEQt 14.0 Yes/No Yes/Yes Yes

He et al [48], 2024, China 4-arm RCT ISI>7 and PSQI global >5 (67.68±4.98) T: 152I1: 38I2: 38I3: 38C: 38 I1: TCu+active rTMSvI2: TC+sham rTMSI3: TC alone Low-intensity PE Primary: ISISecondary: Objective (actigraphy): TST (min), SOL (min), SE (%), WASO (min), number of awakenings, average wake time per awakening. Subjective (sleep diary): daytime sleepiness: Chinese version of the ESS 9.21 Yes/Yes Yes/Yes Yes

Janků et al [49], 2020, Czech Republic 2-arm RCT Diagnosed with insomnia(48.1±16.1) T: 30I: 15C: 15 UVEX S1933X orange glasses UVEX S1900 clear glasses Subjective (sleep diaries): SOL (min), TST (min), WASO (min), SE (%), SQwObjective (actigraphy): SOL (min), TST (min), WASO (min), SE (%) 14.29 No/No No/No Yes

Jeon and Choi [50], 2017, South Korea 2-arm RCT ISI≥15 and PSQI global ≥5(I: 23.5±1.73; C: 25.6±2.88) T: 14I: 5C: 9 Neurofeedback therapy(Procomp 5) Waiting only Objective: TST (min), SLx (min), SE (%) (Smart Wearable Device)Subjective: insomnia symptom severity (ISI), PSQI, ESS, Presleep Arousal Scale (sleep diary) 0 Yes/Yes No/No Yes

Kang et al [51], 2017, South Korea 2-arm RCT Insomnia disorder (45.1±9.8) T: 19I: 10C: 9 Wearable sleep tracker (Fitbit Charge HR) CBT-Iy and app only Objective: SE (%) (actigraphy)Subjective: sleep quality (PSQI), insomnia symptom severity (ISI), SE (%) (PSQI), TST (min), SL (min), TIBz (min), SE (%) (sleep diary) 0 No/No No/No Yes

Kennedy et al [53], 2023, United States 2-arm RCT ISI≥8 (51.18±10.50) T: 30I: 15C: 15 CeraZ Technologies LLC Sham device Objective (oura ring): SE (%), TST (min), TIB (min), SOL (min)Subjective (sleep diaries): SOL (min), sleep quality, Karolinska Sleepiness Scale scores 0 No/No No/Yes Yes

Lee et al [41], 2024, Korea 2-arm RCT ISI≥8 BDI-II=20 (I: 49.40±11.76; C: 48.67±12.90) T: 38I: 20C: 18 MAVE device Sham device Subjective: PSS, BDI-IIaa, ISI, PSQI, STAIab, WHOQOL-BREFacObjective: qEEGad, ACTH, cortisol, BDNFae 16.33 No/No Yes/Yes Yes

Liu et al [52], 2025, China 2-arm RCT Sleep disorders, experiencing MCIaf without dementia (67.9±4.6) T: 110I: 55C: 55 rTMS+TC Sham rTMS+ TC Objective: (actigraphy) SE, SOL, WASO, TSTSubjective: PSQI, ESS, HAMAag, HAMDah, MoCAai 6.4 Yes/No Yes/Yes Yes

Simons et al [54], 2024, United States 2-arm RCT ISI≥8 (MIaj: 52; MCak: 50.5) T: 24I: 12C:12 SDR-tESal (wearable device) Active control Primary: SOLSecondary: TST, WASO, ISI, SE, STAI (state subform) 0 No/Yes No/Yes Yes

Yeom et al [55], 2025, South Korea 2-arm RCT ICSD-3am, PSQI≥5(I: 31.9±12.3; C: 29.4±8.0) T: 40I: 20C: 20 Transcutaneous auricular vagus nerve stimulation Sham device Objective: (Fitbit) TSTSubjective: PSQI, ISI, WHOQOL-BREF 2.5 Yes/Yes Yes/Yes Yes

Zabrecky et al [56], 2020, United States 2-arm RCT Insomnia disorder(I: 43.3±19.6; C: 40.8±1.6) T: 30I: 19C: 11 VibrAcoustic Wellness System Waiting only Objective: (actigraphy) neurological assessment: resting state functional magnetic resonance imagingSubjective: ISI 23.08 No/No No/No Yes

aITT: intention-to-treat analysis.

bMDM: missing data management.

cRCT: randomized controlled trial.

dISI: insomnia severity index.

ePSQI: Pittsburgh Sleep Quality Index.

fT: total.

gI: intervention.

hC: control.

idBTi: digital behavioral therapy for insomnia.

jESS: Epworth Sleepiness Scale.

kWASO: wake after sleep onset.

lSE: sleep efficiency.

mTST: total sleep time.

nEEG: electroencephalography.

oSOL: sleep-onset latency.

pcTBS: continuous theta burst stimulation.

qTA: time awake.

rSFI: sleep fragmentation index.

sVAS: visual analog scale.

tMEQ: Morningness–Eveningness Questionnaire.

uTC: Tai Chi.

vrTMS: repetitive transcranial magnetic stimulation.

wSQ: sleep quality.

xSL: sleep latency.

yCBT-I: cognitive behavioral therapy for insomnia.

zTIB: time in bed.

aaBDI-II: Beck Depression Inventory-II.

abSTAI: State Trait Anxiety Index.

acWHOQOL-BREF: World Health Organization Quality of Life‑BREF.

adqEEG: Quantitative electroencephalography.

aeBDNF: brain‑derived neurotrophic factor.

afMCI: mild cognitive impairment.

agHAMA: Hamilton Anxiety Rating Scale.

ahHAMD: Hamilton Depression Rating Scale.

aiMoCA: Montreal Cognitive Assessment.

ajMI: median intervention.

akMC: median control.

alSDR-tES: short duration repetitive transcranial electric stimulation.

amICSD-3: International Classification of Sleep Disorders‑Third Edition.

Results of Syntheses

ISI

ISI scores were reported in 10 studies. The pooled random-effects estimate, using the HKSJ correction, showed no significant reduction in ISI scores (MD −1.82, 95% CI −4.33 to 0.69, PI −8.95 to 5.31), with substantial between-study heterogeneity (I²=73.2%; Figure 2).

Objective Sleep Outcomes

A series of meta-analyses was conducted for objective TST (n=9), SOL (n=5), WASO (n=5), SE (n=7), and the ESS (n=2), as shown in Figure 3. For TST, the random-effects meta-analysis using the HKSJ correction showed a nonsignificant pooled MD of 17.91 (95% CI −4.39 to 40.22; PI −26.78 to 62.60) minutes. For SOL, a significant reduction was observed, with a pooled MD of −4.52 (95% CI −8.38 to −0.67; PI −9.52 to 0.47) minutes, indicating that wearable interventions shortened the time to fall asleep compared with controls. The meta-analyses found that wearable interventions did not have a statistically significant effect on WASO (MD 2.68, 95% CI −4.00 to 9.37, PI −6.30 to 11.39 minutes), SE (MD 2.10%, 95% CI −3.74% to 7.95%; PI −12.47% to 16.67%), and ESS (MD 2.60, 95% CI −8.60 to 13.80; PI −13.34 to 18.54 points).

Subjective Sleep Outcomes

Meta-analyses were conducted for subjective sleep outcomes, including TST (n=4), SOL (n=4), WASO (n=3), SE (n=4), ESS (n=3), sleep quality (n=3), and PSQI (n=5), as shown in Figure 4. Subjective SE showed a small beneficial effect (MD 2.00%, 95% CI 1.90%‐2.11%; PI 1.85%‐2.15%) in the wearable group compared with controls. Subjective TST was significantly improved (MD 19.11, 95% CI 2.98‐35.24; PI −16.20 to 54.43 min), suggesting inconsistent efficacy across individual trials despite the statistically significant pooled overall effect. For the remaining subjective sleep end points, all 95% CIs crossed the null value and demonstrated no statistically meaningful intervention benefits: subjective SOL (MD −4.0, 95% CI −13.15 to 5.14; PI −16.46 to 8.46 min), subjective WASO (MD −1.86, 95% CI −27.88 to 24.15; PI −8.95 to 5.31 min), subjective ESS (MD −0.22, 95% CI −3.37 to 2.93, PI −5.70 to 5.26 points), subjective sleep quality (MD 0.01, 95% CI −0.38 to 0.40, PI −0.45 to 0.47 points), and PSQI (MD −1.61, 95% CI −3.71 to 0.49; PI −6.03 to 2.81 points).

Investigation of Heterogeneity: Meta-Regression

Subgroup analyses were predefined for multiple sleep outcomes; however, most end points had fewer than 5 trials, precluding reliable subgroup pooling. Accordingly, mixed-effects meta-regression with Hartung-Knapp adjustment was selected as an alternative method to investigate between-study heterogeneity. To identify potential sources of substantial between-study heterogeneity for the ISI, we performed mixed-effects meta-regression with 3 predefined study-level moderators: control type, intervention duration, and device-wearing position. A multivariate model incorporating all 3 covariates was constructed first, followed by 3 separate univariate meta-regression analyses for individual moderator assessment.

In the multivariate regression model, the omnibus F test for combined moderators was nonsignificant (F3,6=0.26; P=.85), and these covariates collectively explained 0.00% of interstudy heterogeneity (R²=0.00%). Marked unexplained residual heterogeneity remained after adjustment (residual I²=83.48%; residual heterogeneity Q‑statistic, QE=29.08; df=6 for QE; P<.001). None of the 3 moderators yielded statistically significant regression coefficients (control type: P=.83; intervention duration: P=.58; device‑wearing position: P=.60; Table 2). Consistent findings were observed in subsequent univariate analyses: control type (F1,8=0.29; P=.61), intervention duration (F1,8=0.60; P=.46), and device-wearing position (F1,8=0.10; P=.76) failed to alter pooled effect estimates. All univariate models returned R² of 0.00%, with residual I² ranging from 78.60% to 80.96%. Overall, the 3 prespecified clinical factors could not account for the high heterogeneity of pooled ISI results.

Table 2.Meta-regression analysis of potential moderators for the insomnia severity index (ISI).

Moderator Coefficient Standard error t test (df) P value 95% CI R² (%)a Residual I² (%)b

Multivariate model

 Control type 0.749 3.28 0.228 (6) .83 −7.276 to 8.773 0 83.48

 Intervention duration 1.883 3.235 0.582 (6) .58 −6.033 to 9.800 0 83.48

 Device-wearing position 1.723 3.124 0.552 (6) .60 −5.922 to 9.368 0 83.48

Univariate model

 Control type 1.281 2.396 0.535 (8) .61 −4.244 to 6.806 0 79.81

 Intervention duration 1.807 2.329 0.776 (8) .46 −3.564 to 7.177 0 78.6

 Device-wearing position 0.85 2.674 0.318 (8) .76 −5.316 to 7.016 0 80.96

aR²: percentage of between-study heterogeneity explained by moderators.

bI²: residual unexplained heterogeneity.

RoB in Studies

The RoB in the included RCTs was independently assessed by 2 reviewers using the Cochrane RoB 2.0 tool. Any disagreements were resolved by consensus or consultation with a third investigator. Overall, 4 studies were classified as having a low RoB, 9 as having an unclear RoB, and 3 as having a high RoB (Figure 5).

Reporting Biases

For the ISI outcome, which included 10 RCTs, we generated funnel plots and applied the random-effects regression test (the regtest function in the metafor package) to assess small-study effects rather than publication bias. We found borderline nonsignificant funnel asymmetry (z=−1.85; P=.06). No quantitative tests for small-study effects were undertaken for the remaining outcomes, as fewer than 10 studies were available, leading to low statistical power.

Sensitivity Analysis

Leave-one-out sensitivity analysis was performed under the HKSJ random-effects model to verify the robustness of the pooled ISI estimate. Sequential exclusion of each individual study did not substantially alter the direction and magnitude of the pooled effect. Excluding the small-sample trial conducted by Jeon and Choi [50] eliminated between-study heterogeneity, yet the overall effect remained consistent, which further confirmed the stability of our primary findings.

Certainty of Evidence

The GRADE rating results (Table 3) showed that 2 outcomes were rated as moderate certainty due to imprecision, and 3 outcomes were rated as high certainty. Outcomes with fewer than 3 studies were not graded.

Table 3.GRADEa summary-of-findings table for wearable digital therapy in adults with insomnia.

Certainty assessment Patients, n/N (%) Effect Certainty

Number of studies Study design Risk of bias Inconsistency Indirectness Imprecision Other considerations Wearable device Control Absolute (95% CI)

Insomnia severity index

10 Randomized trials Not serious Seriousb Not serious Seriousc None 199/383 (52.0) 184/383 (48.0) MDd –1.82 (–4.33 to 0.69) ⨁⨁◯◯ Lowb,c

Pittsburgh Sleep Quality Index

5 Randomized trials Not serious Seriouse Not serious Seriousf None 156/318 (49.1) 162/318 (50.9) MD –1.61 (–3.71 to 0.49) ⨁⨁◯◯ Lowe,f

Objective total sleep time

9 Randomized trials Not serious Seriousg Not serious Serioush None 198/398 (49.7) 200/398 (50.3) MD 17.91 (−4.39 to 40.22) ⨁⨁◯◯ Lowg,h

Subjective total sleep time

4 Randomized trials Not serious Not serious Not serious Not serious None 89/182 (48.9) 93/182 (51.1) MD 19.11 (2.98 to 35.24) ⨁⨁⨁⨁ High

Objective sleep efficiency

7 Randomized trials Not serious Seriousi Not serious Seriousj None 140/290 (48.3) 150/290 (51.7) MD 2.10 (−3.74 to 7.95) ⨁⨁◯◯ Lowi,j

Subjective sleep efficiency

4 Randomized trials Not serious Not serious Not serious Not serious None 109/220 (49.5) 111/220 (50.5) MD 2.00 (1.90 to 2.11) ⨁⨁⨁⨁ High

Objective sleep-onset latency

5 Randomized trials Not serious Not serious Not serious Not serious None 80/164 (48.8) 84/264 (31.8) MD −4.52 (−8.38 to −0.67) ⨁⨁⨁⨁ High

Subjective sleep-onset latency

4 Randomized trials Not serious Not serious Not serious Seriousk None 89/182 (48.9) 93/182 (51.1) MD –4.0 (−13.15 to 5.14) ⨁⨁⨁◯ Moderatek

Objective WASOl

5 Randomized trials Not serious Not serious Not serious Seriousm None 113/231 (48.9) 118/231 (51.1) MD 2.68 (−4.00 to 9.37) ⨁⨁⨁◯ Moderatem

aGRADE: Grading of Recommendations, Assessment, Development, and Evaluation.

bDowngraded one level for substantial heterogeneity (I²=73.2%, P<.001).

cDowngraded one level for wide CI crossing the null (95% CI −4.33 to 0.69) and broad prediction interval.

dMD: mean difference.

eDowngraded one level for moderate-to-substantial heterogeneity (I²=58.3%; P=.026).

fDowngraded one level for CI crossing the null (95% CI −2.73 to 0.45) and broad prediction interval.

gDowngraded one level for moderate heterogeneity (I²=61.3%; P=.008).

hDowngraded one level for CI crossing the null (95% CI −4.39 to 40.22) and very broad prediction interval (−26.78 to 62.60).

iDowngraded one level for substantial heterogeneity (I²=79.0%; P<.0001), largely driven by a single outlier (Jeon and Choi [50]) with an opposite effect direction; sensitivity analysis excluding this study reduced heterogeneity to 39.9% but the pooled estimate remained nonsignificant.

jDowngraded one level for wide CI crossing the null (95% CI −3.74 to 7.95) and very broad prediction interval (−12.47 to 16.67), indicating substantial uncertainty in the true-effect estimate.

kDowngraded one level for serious imprecision. The wide 95% CI (−13.15 to 5.14) crosses the null, including both beneficial and harmful effects, so a clinically meaningful intervention effect cannot be confirmed.

lWASO: wake after sleep onset.

mDowngraded one level for CI crossing the null (−4.00 to 9.37) and being relatively wide, indicating that the true effect could range from a modest reduction to a clinically meaningful increase in WASO.

Discussion

This systematic review and meta-analysis of 16 RCTs encompassing 910 participants indicates that stand-alone wearable digital interventions are associated with small yet statistically significant improvements in objective SOL, subjective SE, and subjective TST among adults with insomnia. Nevertheless, these interventions demonstrate no significant benefit for global insomnia severity as measured by the ISI. Through the application of the HKSJ framework with Nagashima-corrected PIs, this study provides more robust effect estimates than prior reviews. Although pooled estimates favor wearable interventions for these specific parameters, the wide 95% PIs suggest that the effect in any given future clinical setting could range from meaningful benefit to negligible or no effect. This implies that while wearable interventions are validated at the population level for certain sleep outcomes, their real-world effectiveness is highly dependent on context [57-59]. This finding underscores the importance of exploring sources of heterogeneity, a prespecified objective of this review. The certainty of the evidence was rated as moderate to low using GRADE [39], reflecting consistent effect direction for specific outcomes while also acknowledging recognized methodological limitations, particularly the inability to blind participants and outcome assessors in wearable device trials.

The selective efficacy pattern observed in this review suggests that wearable devices target specific physiological and perceptual sleep domains rather than the multifaceted cognitive and behavioral pathology that underlies insomnia disorder [60,61]. This interpretation aligns with the theoretical understanding that insomnia is not merely a disorder of sleep physiology but also involves maladaptive cognitions, conditioned arousal [62], and behavioral factors [63] that require targeted psychotherapeutic intervention [2]. Hardware-based biofeedback and neuromodulation delivered via wearable devices may facilitate physiological de-arousal and shorten sleep onset [54,64,65]; however, they do not directly address the perpetuating mechanisms of insomnia, such as sleep-related worry, conditioned bed arousal, and irregular sleep schedules, that CBT-I is designed to modify [2,60,66]. The certainty of these findings, however, must be tempered by the underlying evidence quality: objective SOL and subjective SE were rated as high certainty by GRADE, providing confidence that wearable devices produce measurable improvements in these specific parameters. By contrast, subjective TST, though statistically significant, was based on only 4 trials and exhibited a wide PI. Its GRADE rating was high primarily due to consistency across the limited number of studies, a finding that should be interpreted with caution given the small evidence base. Furthermore, the overall RoB assessment (Figure 5) showed that most included trials had unclear or high RoB across multiple domains. Insufficient blinding of participants and personnel, an inherent challenge in wearable device trials, was the most common concern [67] and may have inflated effect estimates for subjective outcomes that rely on self-report. Empirical evidence from meta-epidemiological studies shows that nonblinded assessors exaggerate effect estimates for subjective outcomes by 29% (95% CI, 8‑45) on average [67], and a systematic review reported a 68% exaggeration [68]. These findings suggest that the true effects of wearable interventions on subjective sleep outcomes may be smaller than observed. Additionally, several studies had high or unclear RoB due to incomplete outcome data, such as attrition rates exceeding 20% in some trials, a lack of intention-to-treat analysis, or inadequate reporting of randomization and allocation concealment. These methodological limitations, especially when combined with small sample sizes and variable adherence, suggest that the observed effects may be overestimated. Consequently, our more modest and selective findings, compared with larger effect sizes reported for comprehensive digital CBT-I, likely reflect the genuine stand-alone contribution of wearable hardware rather than the confounded psychotherapeutic effects present in prior pooled analyses.

The subjective-objective discrepancy identified in our analysis is consistent with the well-documented phenomenon of sleep misperception in insomnia. Patients with insomnia often underestimate their sleep duration and overestimate their wakefulness relative to objective recordings, a pattern known as paradoxical insomnia or sleep-state misperception [69,70]. Our finding that objective SOL shortened, whereas subjective TST exhibited considerable between-study variability implies that wearable devices may induce genuine physiological changes in sleep onset without necessarily correcting the perceptual distortions that characterize insomnia [61]. This observation has direct implications for patient counseling: individuals using wearable devices may experience faster objective sleep onset but may not perceive a corresponding improvement in overall sleep quality or duration, which could lead to continued dissatisfaction. Ahn et al [71] further showed that greater sleep-wake state discrepancy was associated with poorer treatment response, indicating that unresolved perceptual distortions may undermine perceived treatment benefit even when objective sleep metrics improve.

In comparison with existing syntheses, the modest therapeutic impact of stand-alone wearables becomes apparent. Unlike digital CBT-I programs evaluated in previous reviews [29,30], which address both sleep physiology and the cognitive behavioral perpetuating factors of insomnia, our exclusive focus on wearable hardware reveals improvements limited to specific sleep parameters rather than global insomnia resolution. Reviews of consumer sleep technology [31,32] have largely focused on measurement rather than therapeutic efficacy and did not quantitatively compare different device types or intervention durations. Lai et al [33] previously conducted a review that specifically examined wearable-delivered interventions but pooled heterogeneous populations and did not target insomnia disorder exclusively. Our findings advance this prior work by demonstrating that, in a homogeneous insomnia population, wearables produce selective benefits that are significant for sleep onset and perceived efficiency but not for global insomnia severity, thereby clarifying their appropriate role as adjunctive rather than primary interventions.

From a methodological perspective, the application of Nagashima-corrected PIs [34] offers a more nuanced interpretation than conventional confidence intervals alone. For example, although objective SOL demonstrated a statistically significant average effect, the PI suggested that the true effect in future individual settings could range from meaningful benefit to negligible change or even no effect. Similarly, the significant average improvement in subjective TST was accompanied by a PI that crossed zero, implying that the perceived benefit is inconsistent across settings and may depend on unmeasured moderators, such as baseline sleep misperception severity, device engagement, or placebo expectations. This distinction between average effects and effect distributions is of paramount importance for clinical decision-making: a statistically significant confidence interval confirms that an intervention works on average across trials, whereas the PI reveals whether it is likely to work in a particular clinical setting or for a given individual patient [58].

The high unexplained heterogeneity for ISI (residual I²=83.48% after meta-regression) is noteworthy. The inability of control type, intervention duration, and device-wearing position to explain this heterogeneity implies that the true variability in treatment effects may be attributable to factors that were not captured in published aggregate data. One such factor may be baseline objective sleep duration. Bathgate et al [72] showed that patients with insomnia with objectively measured short sleep duration (<6 h) exhibited a significantly blunted response to CBT-I compared with those with normal sleep duration (≥6 h), suggesting that patients with a more biologically severe insomnia phenotype may be less responsive to behavioral interventions in general. If baseline objective sleep duration similarly moderates response to wearable devices, its absence from the included trials may account for at least part of the unexplained heterogeneity we observed. Other potential sources include baseline insomnia severity, comorbid mental health conditions, concomitant sleep medication use, and individual differences in sleep physiology and perception. Head-worn devices typically use EEG, which provides a direct and physiologically precise measure of sleep and may enable more targeted neuromodulation [73,74]. In contrast, wrist-worn actigraphy, while convenient, is prone to overestimating sleep by misclassifying quiet wakefulness as sleep [75]. Furthermore, inconsistent operational standards for wearable device calibration across different manufacturers could also contribute to measurement variation [27,76]. Of note, although device-wearing position differed across included trials, our prespecified meta-regression confirmed that such hardware divergence was not a statistically significant source of heterogeneity for ISI.

The RoB and GRADE assessments provide important context for our findings. Of the 16 included trials, 9 had an unclear overall RoB and 3 had a high risk, largely attributable to the inherent difficulty of blinding participants and personnel in wearable device trials [39]; consequently, the pooled estimates may be subject to performance and detection bias. The direction of such bias likely favors the intervention group, meaning that the true effects may be smaller than observed. According to the GRADE assessment, 3 outcomes were rated as high certainty, 2 as moderate certainty, and 4 as low certainty (Table 3). The high-certainty outcomes provide confidence that wearable devices produce measurable improvements in these specific parameters. By contrast, the moderate- and low-certainty ratings for the remaining outcomes, resulting from imprecision, inconsistency, or both, indicate that the true effects may differ materially from the pooled estimates, and clinical recommendations derived from these outcomes should be viewed as conditional rather than definitive.

Several limitations should be considered when interpreting the findings of this review. First, the modest number of studies contributing to several pooled outcomes (fewer than 5 trials for roughly half of the analyses) constitutes an important limitation that restricts the statistical reliability of the corresponding estimates and precludes meaningful meta-regression for these end points. The inability to obtain individual patient data further prevented the exploration of patient-level predictors of treatment response, which likely represent key sources of the unexplained heterogeneity we observed for ISI [57]. Future studies with larger numbers of trials and standardized reporting of individual-level characteristics are needed to confirm the robustness of these findings. Second, the predominance of unclear or high RoB across most included trials, primarily due to insufficient blinding as an inherent challenge in wearable device trials, may have inflated effect estimates for subjective outcomes that rely on self-report. Moreover, most trials had intervention durations of 3 months or less, so the long-term efficacy and sustainability of wearable interventions beyond this timeframe remain unknown [77]. Future trials should incorporate longer follow-up periods and more rigorous blinding procedures where feasible. Third, most participants were of East Asian or North American origin, with limited representation from other regions; females predominated, and mean ages varied substantially. Therefore, the findings may not be generalizable to male-only populations, younger adults, or non-Asian and non-Western populations. Future research should prioritize diverse and representative samples to enhance generalizability.

These findings have several practical clinical implications. Consistent with the objective-subjective outcome discrepancy we identified, wearable devices should be considered an adjunct rather than a substitute for first-line CBT-I. This view is supported by Spina et al [61], who found that providing feedback on wearable-measured sleep data reduced insomnia severity (d=0.51), although this effect was modest compared with established CBT-I effect sizes (d=0.85). These devices provide objective sleep biofeedback and facilitate continuous monitoring. Head-mounted EEG equipment enables precise physiological measurement, whereas wrist-worn trackers may overestimate sleep duration [27,76]; therefore, head-worn devices may be better suited for improving objective sleep parameters, although cost and tolerability must be carefully considered in clinical practice. The selective efficacy pattern suggests that wearables may be most appropriate for patients with predominant sleep-onset difficulties or those who perceive their sleep as inefficient. Clinicians should consider baseline patient characteristics, including insomnia subtype, comorbidity, and treatment expectations, when recommending wearables, and they should manage expectations concerning the likely magnitude and consistency of benefit. For future research, large and long-term RCTs are needed to establish long-term efficacy. Novel trials should collect detailed participant baseline data to address unexplained heterogeneity and should include daytime function and quality-of-life outcomes. The integration of wearable real-time feedback with digital CBT-I represents a promising avenue for individualized insomnia management.

This meta-analysis has several strengths. It strictly followed Cochrane systematic review guidance, and the literature search was updated as of May 2026 with 2 newly added RCTs. Stratified analyses that separated objective and subjective sleep indicators helped clarify the distinct discrepancy in efficacy between physiological recordings and patient-reported outcomes. Meta-regression was used instead of fragmented subgroup analyses to systematically explore prespecified confounding moderators contributing to ISI heterogeneity, consistent with current methodological standards. Comprehensive methodological assessments, including RoB evaluation, small-study effect detection via Egger test, leave-one-out sensitivity analysis, and GRADE certainty ratings, further strengthened the reliability and transparency of the results.

In conclusion, the evidence from this review positions stand-alone wearable devices as a potentially valuable but limited tool in the insomnia therapeutic landscape. Their greatest promise likely lies not in replacing first-line therapies but in serving as an objective feedback mechanism and monitoring adjunct that could enhance patient engagement and enable treatment personalization. To move beyond the current paradigm of population-level efficacy but context-dependent effectiveness, the field must pivot from simple efficacy trials toward implementation science. Future research should prioritize the development and evaluation of hybrid models that combine wearable biofeedback with digital CBT-I, invest in large-scale, long-term pragmatic trials across diverse populations, and leverage individual patient data to clarify the heterogeneity of response. By doing so, it becomes possible to unlock the full potential of wearable therapeutics, shifting from a one-size-fits-all approach toward a stratified insomnia management pathway that aligns technological capabilities with patients’ specific pathophysiological and psychological profiles.

Supplementary material

References

1.Benjafield AV Sert Kuniyoshi FH Malhotra A et alEstimation of the global prevalence and burden of insomnia: a systematic literature review-based analysis Sleep Med Rev Aug2025 82 102121 doi10.1016/j.smrv.2025.102121 Medline40627924 PMC12676268

2.Perlis ML Posner D Riemann D Bastien CH Teel J Thase M Insomnia Lancet Sep242022 400 10357 1047 1060 doi10.1016/S0140-6736(22)00879-0 Medline36115372

3.Morin CM Buysse DJ Management of insomnia N Engl J Med 07182024 391 3 247 258 doi10.1056/NEJMcp2305655 Medline39018534

4.Bishop TM Walsh PG Ashrafioun L Lavigne JE Pigeon WR Sleep, suicide behaviors, and the protective role of sleep medicine Sleep Med Feb2020 66 264 270 doi10.1016/j.sleep.2019.07.016 Medline31727433

5.Sutton EL Insomnia Ann Intern Med Mar2021 174 3 ITC33 ITC48 doi10.7326/AITC202103160 Medline33683929

6.Taddei-Allen P Economic burden and managed care considerations for the treatment of insomnia Am J Manag Care Mar2020 26 4 Suppl S91 S96 doi10.37765/ajmc.2020.43008 Medline32282179

7.Luyster FS Strollo PJ Zee PC Walsh JK Boards of Directors of the American Academy of Sleep Medicine and the Sleep Research SocietySleep: a health imperative Sleep Jun12012 35 6 727 734 doi10.5665/sleep.1846 Medline22654183 PMC3353049

8.Jung S Takeuchi T Kitahara M Tsutsumi A Nomura K Effectiveness of mobile applications in improving insomnia symptoms among adults from multi-community: a systematic review and meta-analysis Sleep Med 072024 119 357 364 doi10.1016/j.sleep.2024.05.020 Medline38761604

9.Dopheide JA Insomnia overview: epidemiology, pathophysiology, diagnosis and monitoring, and nonpharmacologic therapy Am J Manag Care Mar2020 26 4 Suppl S76 S84 doi10.37765/ajmc.2020.42769 Medline32282177

10.Wickwire EM Shaya FT Scharf SM Health economics of insomnia treatments: the return on investment for a good night’s sleep Sleep Med Rev Dec2016 30 72 82 doi10.1016/j.smrv.2015.11.004 Medline26874067

11.Dressle RJ Spiegelhalder K Schiel JE et alThe future of insomnia research: there’s still work to be done J Sleep Res Oct2025 34 5 e70091doi10.1111/jsr.70091 Medline40344330 PMC12426721

12.Kessler RC Berglund PA Coulouvrat C et alInsomnia and the performance of US workers: results from the America insomnia survey Sleep Sep12011 34 9 1161 1171 doi10.5665/SLEEP.1230 Medline21886353 PMC3157657

13.Shang L Zhao Y Cong A et alPrevalence, subtypes, and comorbidity of DSM-5 insomnia disorder among adults in Beijing, China: a large-scale cross-sectional study BMC Public Health Feb52026 26 1 827doi10.1186/s12889-026-26453-x Medline41639643 PMC12973733

14.Hwang H Kim KM Yun CH Yang KI Chu MK Kim WJ Sleep state of the elderly population in Korea: nationwide cross-sectional population-based study Front Neurol 2022 13 1095404doi10.3389/fneur.2022.1095404 Medline36698878 PMC9868806

15.Bassetti CLA Welter LS Montes-Martinez M et alEpidemiology and economic burden of sleep disorders in Europe Eur J Neurol Feb2026 33 2 e70463doi10.1111/ene.70463 Medline41689412 PMC12905625

16.Oliver S Dombek K Milner AE Harvey AG Innovative approaches to advancing equitable access to insomnia interventions Curr Sleep Med Rep 2026 12 1 36doi10.1007/s40675-026-00385-9 Medline42358907 PMC13291000

17.Jennings M Treger M Zhou E Cheng P 0565 Behavioral insomnia treatment accessibility in the US: a real-world assessment of cost, location, and availability Sleep 05192025 48 Supplement_1 A246 A246 doi10.1093/sleep/zsaf090.0565

18.Durante JC Gomes Dantas A Coelho Inouye F et alProlonged use of benzodiazepine in primary health care: evaluation of effectiveness, dependence and cognitive function Expert Opin Drug Saf Sep292025 1 10 doi10.1080/14740338.2025.2567587 Medline40996880

19.Modesto-Lowe V Chaplin MM León-Barriera R Jain L Reducing the risks when using benzodiazepines to treat insomnia: a public health approach Cleve Clin J Med 0512024 91 5 293 299 doi10.3949/ccjm.91a.23061 Medline38692699

20.Qaseem A Kansagara D Forciea MA Cooke M Denberg TD Clinical Guidelines Committee of the American College of PhysiciansManagement of Chronic Insomnia Disorder in Adults: A Clinical Practice Guideline From the American College of Physicians Ann Intern Med 07192016 165 2 125 133 doi10.7326/M15-2175 Medline27136449

21.Ginsburg GS Picard RW Friend SH Key issues as wearable digital health technologies enter clinical care N Engl J Med Mar212024 390 12 1118 1127 doi10.1056/NEJMra2307160 Medline38507754

22.Abd-Alrazaq A AlSaad R Aziz S et alWearable artificial intelligence for anxiety and depression: scoping review J Med Internet Res 01192023 25 e42672doi10.2196/42672 Medline36656625 PMC9896355

23.Luik AI Farias Machado P Espie CA Delivering digital cognitive behavioral therapy for insomnia at scale: does using a wearable device to estimate sleep influence therapy? NPJ Digit Med 2018 1 3doi10.1038/s41746-017-0010-4 Medline31304289 PMC6548338

24.Resmed’s global sleep survey reveals sleep is one of the top health priorities, but quality rest remains out of reach Nasdaq URLhttps://www.nasdaq.com/press-release/resmeds-global-sleep-survey-reveals-sleep-one-top-health-priorities-quality-rest-0Accessed29-06-2026

25.Wearable sleep trackers market report 2026 The Business Research Company2026 URLhttps://www.researchandmarkets.com/reports/6104218/wearable-sleep-trackers-market-reportAccessed29-06-2026

26.Abd-Alrazaq A AlSaad R Shuweihdi F Ahmed A Aziz S Sheikh J Systematic review and meta-analysis of performance of wearable artificial intelligence in detecting and predicting depression NPJ Digit Med 0552023 6 1 84doi10.1038/s41746-023-00828-5 Medline37147384 PMC10163239

27.de Zambotti M Cellini N Goldstone A Colrain IM Baker FC Wearable sleep technology in clinical and research settings Med Sci Sports Exerc 072019 51 7 1538 1557 doi10.1249/MSS.0000000000001947 Medline30789439 PMC6579636

28.Abd-Alrazaq A AlSaad R Harfouche M et alWearable artificial intelligence for detecting anxiety: systematic review and meta-analysis J Med Internet Res Nov82023 25 e48754doi10.2196/48754 Medline37938883 PMC10666012

29.Bai N Cao J Zhang H Liu X Yin M Digital cognitive behavioural therapy for patients with insomnia and depression: a systematic review and meta-analysis J Psychiatr Ment Health Nurs Aug2024 31 4 654 667 doi10.1111/jpm.13024 Medline38226714

30.Hwang JW Lee GE Woo JH Kim SM Kwon JY Systematic review and meta-analysis on fully automated digital cognitive behavioral therapy for insomnia NPJ Digit Med Mar122025 8 1 157doi10.1038/s41746-025-01514-4 Medline40075149 PMC11903857

31.Baron KG Duffecy J Berendsen MA Cheung Mason I Lattie EG Manalo NC Feeling validated yet? A scoping review of the use of consumer-targeted wearable and mobile technology to measure and improve sleep Sleep Med Rev Aug2018 40 151 159 doi10.1016/j.smrv.2017.12.002 Medline29395985 PMC6008167

32.Glazer Baron K Culnan E Duffecy J et alHow are consumer sleep technology data being used to deliver behavioral sleep medicine interventions? A systematic review Behav Sleep Med 2022 20 2 173 187 doi10.1080/15402002.2021.1898397 Medline33757392 PMC8493561

33.Lai MYC Mong MSA Cheng LJ Lau Y The effect of wearable-delivered sleep interventions on sleep outcomes among adults: a systematic review and meta-analysis of randomized controlled trials Nurs Health Sci Mar2023 25 1 44 62 doi10.1111/nhs.13011 Medline36572659

34.Nagashima K Noma H Furukawa TA Prediction intervals for random-effects meta-analysis: a confidence distribution approach Stat Methods Med Res Jun2019 28 6 1689 1702 doi10.1177/0962280218773520 Medline29745296

35.Röver C Knapp G Friede T Hartung-Knapp-Sidik-Jonkman approach and its modification for random-effects meta-analysis with few studies BMC Med Res Methodol Nov142015 15 99doi10.1186/s12874-015-0091-1 Medline26573817 PMC4647507

36.Page MJ McKenzie JE Bossuyt PM et alThe PRISMA 2020 statement: an updated guideline for reporting systematic reviews BMJ Mar292021 372 n71doi10.1136/bmj.n71 Medline33782057 PMC8005924

37.Hariton E Locascio JJ Randomised controlled trials—the gold standard for effectiveness research: study design: randomised controlled trials BJOG Dec2018 125 13 1716 doi10.1111/1471-0528.15199 Medline29916205 PMC6235704

38.Rethlefsen ML Kirtley S Waffenschmidt S et alPRISMA-S: an extension to the PRISMA statement for reporting literature searches in systematic reviews Syst Rev 01262021 10 1 39doi10.1186/s13643-020-01542-z Medline33499930 PMC7839230

39.Higgins JPT Thomas J Chandler J et alCochrane Handbook for Systematic Reviews of Interventions 2ndWiley-Blackwell2019 doi10.1002/9781119536604

40.Naunton Morgan B Windle G Sharp R Lamers C eHealth and web-based interventions for informal carers of people with dementia in the community: umbrella review J Med Internet Res 07222022 24 7 e36727doi10.2196/36727 Medline35867388 PMC9356334

41.Lee E Hong JK Choi H Yoon IY Modest effects of neurofeedback-assisted meditation using a wearable device on stress reduction: a randomized, double-blind, and controlled study J Korean Med Sci Mar112024 39 9 e94doi10.3346/jkms.2024.39.e94 Medline38469966 PMC10927393

42.Aji M Glozier N Bartlett DJ et alThe effectiveness of digital insomnia treatment with adjunctive wearable technology: a pilot randomized controlled trial Behav Sleep Med 2022 20 5 570 583 doi10.1080/15402002.2021.1967157 Medline34415819

43.Anderson DJ Troxel WM Landvatter J Baron KG A randomized pilot study of a wearable device using variable complex weak magnetic fields among participants with insomnia symptoms J Clin Sleep Med 0712025 21 7 1285 1291 doi10.5664/jcsm.11690 Medline40165746 PMC12225276

44.Bressler S Neely R Yost RM Wang D Read HL A wearable EEG system for closed-loop neuromodulation of sleep-related oscillations J Neural Eng Oct52023 20 5 doi10.1088/1741-2552/acfb3b Medline37726002

45.Chen Z Li Q He X Zhou Y Continuous theta burst stimulation improves sleep quality and thereby enhances athletic performance in athletes with sleep disorders: a randomized controlled trial J Exerc Sci Fit Apr2026 24 2 200432doi10.1016/j.jesf.2025.200432 Medline41994622 PMC13080906

46.Curry G Cheung T Zhang SD et alRepeated electrical vestibular nerve stimulation (VeNS) reduces severity in moderate to severe insomnia; a randomised, sham-controlled trial; the modius sleep study Brain Stimul 2024 17 4 782 793 doi10.1016/j.brs.2024.05.010 Medline38797370

47.Esaki Y Takeuchi I Tsuboi S Fujita K Iwata N Kitajima T A double-blind, randomized, placebo-controlled trial of adjunctive blue-blocking glasses for the treatment of sleep and circadian rhythm in patients with bipolar disorder Bipolar Disord Nov2020 22 7 739 748 doi10.1111/bdi.12912 Medline32276301

48.He J Chan SHW Chung RCK Tsang HWH Effect of combined Tai Chi and repetitive transcranial magnetic stimulation for sleep disturbance in older adults: a randomized controlled trial J Psychiatr Res Dec2024 180 281 290 doi10.1016/j.jpsychires.2024.10.025 Medline39476538

49.Janků K Šmotek M Fárková E Kopřivová J Block the light and sleep well: evening blue light filtration as a part of cognitive behavioral therapy for insomnia Chronobiol Int Feb2020 37 2 248 259 doi10.1080/07420528.2019.1692859 Medline31752544

50.Jeon J Choi S Insomnia treatment using neurofeedback: EEG beta decrease protocol Korean J Clin Psychol 2017 36 3 351 368 doi10.15842/kjcp.2017.36.3.006

51.Kang SG Kang JM Cho SJ et alCognitive behavioral therapy using a mobile application synchronizable with wearable devices for insomnia treatment: a pilot study J Clin Sleep Med Apr152017 13 4 633 640 doi10.5664/jcsm.6564 Medline28162145 PMC5359343

52.Liu Z Zhang L Bai L et alRepetitive transcranial magnetic stimulation and tai chi chuan for older adults with sleep disorders and mild cognitive impairment: a randomized clinical trial JAMA Netw Open 0122025 8 1 e2454307doi10.1001/jamanetworkopen.2024.54307 Medline39792383 PMC12548080

53.Kennedy KER Wills CCA Holt C Grandner MA A randomized, sham-controlled trial of a novel near-infrared phototherapy device on sleep and daytime function J Clin Sleep Med Sep12023 19 9 1669 1675 doi10.5664/jcsm.10648 Medline37141002 PMC10476031

54.Simons SB Provo M Yanoschak A et alA randomized study on the effect of a wearable device using 0.75 Hz transcranial electrical stimulation on sleep onset insomnia Front Neurosci 2024 18 1427462doi10.3389/fnins.2024.1427462 Medline39507801 PMC11537953

55.Yeom JW Kim H Park S et alTranscutaneous auricular vagus nerve stimulation (taVNS) improves sleep quality in chronic insomnia disorder: a double-blind, randomized, sham-controlled trial Sleep Med Sep2025 133 106579 doi10.1016/j.sleep.2025.106579 Medline40398066

56.Zabrecky G Shahrampour S Whitely C et alAn fMRI study of the effects of vibroacoustic stimulation on functional connectivity in patients with insomnia Sleep Disord 2020 2020 7846914doi10.1155/2020/7846914 Medline32089894 PMC7024098

57.Riley RD Debray TPA Fisher D et alIndividual participant data meta-analysis to examine interactions between treatment effect and participant-level covariates: statistical recommendations for conduct and planning Stat Med 07102020 39 15 2115 2137 doi10.1002/sim.8516 Medline32350891 PMC7401032

58.Borenstein M How to understand and report heterogeneity in a meta-analysis: the difference between I-squared and prediction intervals Integr Med Res Dec2023 12 4 101014doi10.1016/j.imr.2023.101014 Medline38938910 PMC11208730

59.Prediction intervals should be routinely reported in meta-analyses Cochrane Colloquium Abstracts URLhttps://abstracts.cochrane.org/2015-vienna/prediction-intervals-should-be-routinely-reported-meta-analysesAccessed02-07-2026

60.Altena E Ellis J Camart N Guichard K Bastien C Mechanisms of cognitive behavioural therapy for insomnia J Sleep Res Dec2023 32 6 e13860doi10.1111/jsr.13860 Medline36866434

61.Spina MA Andrillon T Quin N Wiley JF Rajaratnam SMW Bei B Does providing feedback and guidance on sleep perceptions using sleep wearables improve insomnia? Findings from “Novel Insomnia Treatment Experiment”: a randomized controlled trial Sleep Sep82023 46 9 zsad167doi10.1093/sleep/zsad167 Medline37294865 PMC10485571

62.Robertson JA Broomfield NM Espie CA Prospective comparison of subjective arousal during the pre-sleep period in primary sleep-onset insomnia and normal sleepers J Sleep Res Jun2007 16 2 230 238 doi10.1111/j.1365-2869.2007.00579.x Medline17542954

63.Harvey AG A cognitive model of insomnia Behav Res Ther Aug2002 40 8 869 893 doi10.1016/s0005-7967(01)00061-4 Medline12186352

64.Ehelagasthenna M Holmquist LE Oliveira C Shahidi AM Lugoda P Hughes-Riley T Haptic pillow sleeve: enhancing sleep quality by providing vital sound awareness through vibrotactile feedback Proc Ext Abstr 2026 CHI Conf Hum Factors Comput Syst 2026 1 6 doi10.1145/3772363.3798362

65.de Zambotti M Sizintsev M Claudatos S Barresi G Colrain IM Baker FC Reducing bedtime physiological arousal levels using immersive audio-visual respiratory bio-feedback: a pilot study in women with insomnia symptoms J Behav Med Oct2019 42 5 973 983 doi10.1007/s10865-019-00020-9 Medline30790211 PMC6703979

66.Ballesio A Bacaro V Vacca M et alDoes cognitive behaviour therapy for insomnia reduce repetitive negative thinking and sleep-related worry beliefs? A systematic review and meta-analysis Sleep Med Rev Feb2021 55 101378 doi10.1016/j.smrv.2020.101378 Medline32992228

67.Salazar J Moustgaard H Bracchiglione J Hróbjartsson A Empirical evidence of observer bias in randomized clinical trials: updated and expanded analysis of trials with both blinded and non-blinded outcome assessors J Clin Epidemiol 072025 183 111787doi10.1016/j.jclinepi.2025.111787 Medline40258524

68.Hróbjartsson A Thomsen ASS Emanuelsson F et alObserver bias in randomized clinical trials with measurement scale outcomes: a systematic review of trials with both blinded and nonblinded assessors CMAJ Mar52013 185 4 E201 E211 doi10.1503/cmaj.120744 Medline23359047 PMC3589328

69.Fernandez-Mendoza J Calhoun SL Bixler EO et alSleep misperception and chronic insomnia in the general population: role of objective sleep duration and psychological profiles Psychosom Med 012011 73 1 88 97 doi10.1097/PSY.0b013e3181fe365a Medline20978224 PMC3408864

70.Vgontzas AN Fernandez-Mendoza J Liao D Bixler EO Insomnia with objective short sleep duration: the most biologically severe phenotype of the disorder Sleep Med Rev Aug2013 17 4 241 254 doi10.1016/j.smrv.2012.09.005 Medline23419741 PMC3672328

71.Ahn JS Bang YR Jeon HJ Yoon IY Effects of subjective-objective sleep discrepancy on the response to cognitive behavior therapy for insomnia J Psychosom Res 012022 152 110682 doi10.1016/j.jpsychores.2021.110682 Medline34864239

72.Bathgate CJ Edinger JD Krystal AD Insomnia patients with objective short sleep duration have a blunted response to cognitive behavioral therapy for insomnia Sleep 0112017 40 1 zsw012doi10.1093/sleep/zsw012 Medline28364452 PMC6084751

73.Miner B Chen A Pan Y et alPerformance of an electroencephalography-measuring headband or actigraphy compared with polysomnography in older adults with sleep disturbances Sleep 05122026 49 5 zsag053doi10.1093/sleep/zsag053 Medline41757511 PMC13058607

74.Markov K Elgendi M Menon C EEG-based headset sleep wearable devices npj Biosensing 2024 1 1 12 doi10.1038/s44328-024-00013-y

75.Nahavandi D Alizadehsani R Khosravi A Acharya UR Application of artificial intelligence in wearable devices: opportunities and challenges Comput Methods Programs Biomed 012022 213 106541 doi10.1016/j.cmpb.2021.106541 Medline34837860

76.Conley S Knies A Batten J et alAgreement between actigraphic and polysomnographic measures of sleep in adults with and without chronic conditions: a systematic review and meta-analysis Sleep Med Rev Aug2019 46 151 160 doi10.1016/j.smrv.2019.05.001 Medline31154154 PMC6594867

77.Jernelöv S Blom K Hentati Isacsson N et alVery long-term outcome of cognitive behavioral therapy for insomnia: one- and ten-year follow-up of a randomized controlled trial Cogn Behav Ther 012022 51 1 72 88 doi10.1080/16506073.2021.2009019 Medline35099359

Come citare questo studio

Wenhui Zhu, Mingming Chen, Yixuan Guo, Bin Zhang, Chunliu Luo. (2026). Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.. Journal of medical Internet research. DOI: 10.2196/93496

Consulta la pubblicazione originale ↗